REASEARCH AND TEACHING INTERESTS
Refrigeration and Heat Pump
Energy Storage and Utilization of Renewable Energy
EDUCATION
PhD in HVAC Engineering, Department of Building Science, Tsinghua University, 2001
Advanced Study and Training, Association for Overseas Technical Scholarship (AOTS) in Japan and Nippon Light Metal Co., LTD. (NKK), 09/1991~09/1992
Master in Refrigeration and Cryogenic Engineering, Department of Refrigeration Engineering, Tianjin University of commerce, 1994
Bachelor in Refrigeration Engineering, Department of Refrigeration Engineering, Tianjin University of commerce, 1986
PROFESSIONAL EXPERIENCE
Doctoral Advisor, Department of Building Science, Tsinghua University, Beijing, China, 12/2009-present
Professor, Department of Building Science, Tsinghua University, 12/2008-present
Associate Professor, Department of Building Science, Tsinghua University, 12/2003-12/2008
Lecturer, Department of Building Science, Tsinghua University, 07/2003-12/2003
Post Doctor and Research Assistant, Department of Thermal Engineering, Tsinghua University, 05/2001-07/2003
Political Tutor and Lecturer, Department of Refrigeration Engineering, Tianjin University of commerce, Tianjin, China, 07/1986-05/2001
RESEARCH PROJECTS
Basic Research
Project of National Natural Science Foundation: Construction and Coupling Characteristics Research of Combined Refrigeration System by Thermo-siphon and Vapor Compression (Grant Number: 51176084) ,01/ 2012-12/2015
Subject of 973 Program: Energy Storage and Release & Active Energy Storage (Grant Number: 2010CB227305), 01/2010-12/2014
Project of National Natural Science Foundation: Double-effect Adjustment Method of Refrigeration and Heat Pump System with Scroll Compressor Based on Refrigerant Injection and Release (Grant Number: 51006059), 01/2011-12/2013
Project of Industry-university-research Cooperation of Guangdong Ministry of Education: Product Research of Air-conditioner with Evaporative Condensing Heat Pipe (Number: 2010B090400154), 02/2010-12/2011
A subject of National Science and Technology Supported Projects: Development of Air Quality Detection and Purification Technology in Urban Underground Space (Number: 2006BAJ27B03-3), 11/2006-12/2010
Project of National Natural Science Foundation: Basic Applied Research of Refrigerant Injection and Extraction Technology in Heat Pump System (Grant Number: 50676042), 01/2007-12/2009
Project of Low Energy Consumption Building Demonstration in the Three Concepts Exhibition Center of Olympic Village (Grant Number: D0606004040391), 07/2006-12/2008
Applied Research
Transverse Project of China Machinery & Electrical Export Products Investment Co., Ltd: Design Code Research and Development of Complement Thermal System for Ground Source Heat Pump, 03/2013-03/2014
Transverse Project of CHANGHONG Group (Sichuan): Control Strategy Research and Standards of VISA System, 01/2013-12/2014
Transverse Project of China Machinery & Electrical Export Products Investment Co., Ltd: Development of Efficient Air Heating Units of Ground Source Heat Pump Applied in Hezhi Railway Station of Shenshuo Railway Corporation, Modulation method of the scroll compressor based on suction gas bypass[J] Applied Thermal Engineering, 2012, (37):183-189
[9] W.X. Shi, L.J. Han, B.L. Wang, et al. Principle of combined air conditioner by heat pipe and vapor compression and its application analysis in high heat density space[J]. Refrigeration and Air-Conditioning, 2011, 11(1):30-36.
[10] W. Zhao, D.H. Zhou, W.X. Shi. Performance domain of multiple-split air conditioning systems[J]. HV & AC, 2010, 40(7):98-102,107.
[11] B.L. Wang, L.J. Han, W.X. Shi, et al. Scroll compressor capacity regulating technology based on the refrigerant escaping[J]. Journal of Refrigeration, 2010, 31(2):7-10. (in Chinese)
[12] B.L. Wang, W.X. Shi, L.J Han, et al. Optimization of refrigeration system with gas-injected scroll compressor. International Journal of Refrigeration, 2009, 32 (7):1544-1554
[13] B.L. Wang, W.X. Shi, X.T. Li. Numerical analysis on the effects of refrigerant injection on the scroll compressor[J], Applied Thermal Engineering, 2009, 29 (1): 37-46.
[14] W.X. Shi, W. Zhao, B.L. Wang. Performance evaluation method of Multi-connected Air- conditioning (heat pump) Systems[J]. Journal of Refrigeration, 2008, 29 (3): 10-17. (in Chinese)
[15] S.Q. Shao, W. X. Shi, X.T. Li, , et al. Simulation model for complex refrigeration systems based on two-phase fluid network - part I: model development[J], International Journal of Refrigeration, 2008, 31(3): 490-499
[16] W.X. Shi, S.Q. Shao, X.T. Li, et al. Simulation model for complex refrigeration systems based on two-phase fluid network - part II: model application[J], International Journal of Refrigeration, 2008, 31(3): 500-509.
[17] W.X. Shi, S.Q. Shao, Q.S. Yan. Effective region of Multi-connected Air-condition (heat pump) System, Journal of Refrigeration, 2007, 28(2): 8-12. (in Chinese)
[18] Shi W.X, Wang B.L, Li X.T. A measurement method of ice layer thickness based on resistance-capacitance circuit for closed loop external melt ice storage tank[J]. Applied Thermal Engineering, 2005, 25 (11-12): 1697-1707.
[19] Shao S.Q., Shi W.X., Li X.T., et al. Performance representation of variable-speed compressor for inverter air conditioners based on experimental data. International Journal of Refrigeration, 2004, 27(8): 805-815.
[20] Shi, W.X., Shao, S.Q., Li, X.T.,et al. A network model to simulate performance of variable speed refrigerant volume refrigeration systems[J]. ASHRAE Transactions, 2003, 109 (2), 61–68.
Writings
[1] Wenxing Shi, Jianhong Cheng, Wei Zhao, et al. Guidelines for the implementation of the relevant standards of multiple-split air conditioning technology[M]. Beijing: China Zhijian Publishing House, March, 2011.
[2] Qisen Yan, Wenxing Shi, Changqing Tian. Refrigeration technology for air-conditioning(the fourth edition)[M]. Beijing: China Architecture & Building Press. July, 2010.
[3] Yanshun Yu, Xianting Li, Wenxing Shi, Zheng Wang. Tailrace Tunnel Ventilation Technology in Hydropower Station and its application[M], Beijing: Science Press, February, 2010
[4] Xianting Li, Wenxing Shi , Bin Zho, etc. Built Environment Science[M], Beijing: China Architecture & Building Press, May, 2006.
[5] Qisen Yan, Jang Shen, Wenxing Shi. Application of Refrigeration Technology [M], Beijing: China Architecture & Building Press, June, 2006.
[6] Wenxing Shi (Translation). Comprehensive Assessment System for Building Environmental Efficiency (CASBEE) [M], Beijing: China Architecture & Building Press, July, 2005.
national standards
[1] GB/T 27941-2011, Application Design and Installation Requirements for multi-split air conditioners(Heat pump) Packages[S].
[2] GB/T17758-2010, Unitary air conditioner[S].
[3] GB/T 25127.1-2010, Low Temperature Air Source Heat Pump (Water Chilling) Packages, part 1: industrial or commercial packages[S].
[4] GB21454-2008, The minimum allowable values of the IPLV and energy efficiency grades for multi-connected air-condition (heat pump) unit[S].